LA3000+ (Logic Analyzer)

{Acute} {Acute}

LA3000+ (Logic Analyzer)

  • PC-based, 68 / 136 channels
  • USB 3.0 interface, 12V power adaptor
  • 2.4GHz Timing Analysis / 300MHz State Analysis
  • 32Gb RAM
  • Active Probes
  • Logic, State, Protocol triggers
  • Stackable with a DSO to form an MSO

Buy

LA3000+ series Model Channel Bus Triggers Protocol Analysis
Acute logic analyzer protocol analyzer LA3000 64ch  LA3068E+  68  I  I
 LA3068B+  68  I, II  I, II
Acute logic analyzer protocol analyzer LA3000  LA3136E+  136  I  I
 LA3136B+  136  I, II  I, II

Bus Triggers I  : I²C, MIPI I3C 1.1, SPI, UART (RS232), USB PD3.0

Bus Triggers II : eMMC5.1, eSPI, I²S, NAND Flash, SD3.0, Serial Flash, SVID, ...

Protocol Analysis I  : I²C, MIPI I3C 1.1, SPI, UART (RS232), USB PD3.0

Protocol Analysis II : CAN 2.0B/CAN-FD, BiSS-C, DALI, eSPI, I²S, LIN2.2, MDIO, PWM, SVID, ...

Bus Decode : CAN 2.0B/CAN-FD, DP_Aux, eMMC 5.1, I²C, MIPI I3C 1.1, Profibus, SD 3.0, SPI,SVID, SWD, UART (RS232), USB1.1, USB PD 3.0... 100+


Introduction

LA3000+ series is an upgrade version of LA3000. It has added the Parallel Clause Trigger function for parallel bus analysis. And it contains Logic Analyzer Mode and Protocol Analyzer Mode for bus analysis and decodes.

(For Parallel Clause Trigger Info, click here)


  • Logic Analyzer(LA) Mode
    Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.

    LA Storage Mode:

    Storage mode
    Long Time Record: Transitional Storage VS Compressed Storage
    For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn't need to do the decompression. The decoded results can be displayed while the analysis is finished. 

    Compressed en
    Transition en

    Software Main Window: LA MODE
    Trigger Settings Window:
    Trigger
    Multiple Protocols Analysis Simultaneously:
    Ex: I2C + USB PD3.0
    MultiProtocol
    LA3000+ Stack With Other Vendors of Oscilloscope:
    (*Support DSO)SMBUS External DSO
    Stack DSO 1 Stack DSO 2

    Add Notes & Pictures in WaveformNote
    Parallel Clause Triggers
    16-States parallel "IF Clause" settings for 128/64 channel value compare combined with AND/OR logic condition and 4 Timer/Counter conditions.
    Parallel Trigger en


  • Protocol Analyzer(PA) Mode
    It is hardware decoding, may log protocol data very long time if without waveforms.
    Application timing: Preliminary protocol debug.

    PA Storage Mode
    PA Storage Type

    Software Main Window
    PA MODE


■ Certification
CEFCC