Supported models for differential signal analysis without adapter:
DP_Aux: All TB3000 series
CAN2.0/CAN-FD: TB3016B Only
RS485: TB3016B Only
TB3000 | Model | Channels | Module | Protocol Decode | Protocol Trigger |
![]() |
TB3016F | 19 | I | 70+ | I |
TB3016E | 19 | I, II | 70+ | I, II | |
![]() |
TB3016B | 25 | I, II, III | 70+ | I, II, III |
Protocol Decode: CAN FD, DALI2.0, DP_Aux, I²C, I²S, LIN2.2, PMBus, PWM, SMBus, SPI, MIPI I3C 1.1, UART, USB PD 3, ... (70+ decodes)
Module I: I²C, RS232, SPI
Module II: HID over I²C, I²S, LIN2.2, MDIO, PMBus, SMBus, USB1.1
Module III: BiSS-C, CAN2.0B, CAN-FD, DALI2.0, Modbus, Profibus, RS422, RS485, USB PD 3, ...
• Differential channels: 2 (CAN2.0B/CAN-FD), 4 (RS422/485)
• Stackable with Acute TravelScope DSO to form an MSO
• Isolated Ground: CAN2.0B/CAN-FD, RS485 (Safety Isolation >1000Vrms)
Introduction
TravelBus 3000 series is usually for Vehicle & Automation Industry measurement. It not only supports the common protocols such as I2C etc. but also supports measuring differential signals such as RS485(EIA485)、RS422、CAN2.0、CAN FD、DP-AUX etc. directly. In addition, the TB3000 series is a 2-in-1 analyzer( Logic Analyzer Mode & Protocol Analyzer Mode )
- Logic Analyzer(LA) Mode
Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.
LA Storage Mode:
Long Time Record: Transitional Storage VS Compressed Storage
For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn't need to do the decompression. The decoded results can be displayed while the analysis is finished.
Software Main Window:
Trigger Settings Window:
Multiple Protocols Analysis Simultaneously:
Ex: I2C + USB PD3.0
TB3000 Stack With Other Vendors of Oscilloscope:
(*Support DSO)
Add Notes & Pictures in Waveform
TravelBus Differential Signal Pin Define
1. DP-AUX:(*SDA->AUX+, SCL->AUX-)
2. CAN 2.0B/CAN FD:(*Only for TB2016B)
3. RS485(EIA 485)/RS422(EIA 422):(*Only for TB2016B)
- Protocol Analyzer(PA) Mode
It is hardware decoding, may log protocol data very long time if without waveforms.
Application timing: Preliminary protocol debug.
PA Storage Mode:
Software Main Window:
If you are looking for higher-speed digital signals, you can refer to other products:
TravelLogic 4000 series
MSO2000 series
LA3000+ series
BusFinder series
■ Certification