The MSO2116E is a 16-channel 3-in-1 (logic, protocol, and oscilloscope) analyzer, with each channel supporting simultaneous measurement of both analog and digital signals. When measuring power management-related protocols, it can not only decode the protocols but also simultaneously record voltage values. Currently, the MSO2000 series offers two different signal and bus analysis modes: logic analyzer mode and protocol analyzer mode.
In the past, many users had questions or were unclear about the voltage threshold settings in the logic analyzer. Therefore, Acute has added a one-click automatic voltage threshold detection and configuration feature in the MSO2000 series products to save users the time required for configuration.
Logic Analyzer (LA) Mode
• Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.
• Provides multiple storage modes, users could select to have long time recording or precision acquisition.
• Long Time Record: Transitional Storage VS Compressed Storage
For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.
Digital and Analog Waveform Settings Each channel supports both digital and/or analog waveforms measurements, voltage resolution can be changed between 2 levels for all channels at the same time
Flow chart bus triggers
Power trigger for serial bus, 8-states flow chart setting with Counter/Timer
Detail parameters for each states
Stack With Other Vendors of Oscilloscope
MSO Enables Digital & Analog Channels (Using the same channels)
Digital & Analog Signals From MSO and External DSO From Other Vendors *[1]: Decode & Digital Signals;*[2]: MSO Analog Signals;*[3]: External DSO Signals
Protocol Analyzer (PA) Mode It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.
Protocol Analyzer Show real-time protocol data. Application timing: massive protocol data with some idles in between.
Protocol Logger Like data logger, save massive data into SSD hard drive. Application timing: massive protocol data.
Protocol Monitor Like dash cameras, record protocol data by the device’s memory only. Application timing: trigger event only happens in very long time.
DSO Spec.
Power source
USB bus-power (+5V)
Static power consumption
0.9W
Max power consumption
<6W
Acquisition Mode
N/A
8 bits Sampling [Record length]
N/A
≧12 bits Sampling [Record length]
200MHz
≧14 bits Sampling [Record length]
N/A
Input channels
16
Input coupling
N/A
Input impedance
N/A
Overvoltage protection
N/A
Ch-Ch isolation
N/A
Ch-Ch skew
N/A
Bandwidth
40 MHz
Rise time
N/A
Resolution
12 bits
Input sensitivity
N/A
Offset range
N/A
DC accuracy
N/A
Bandwidth limit
N/A
Protocol Trigger / Decode
N/A
Electrical Validation (Protocol)
N/A
Cascade
N/A
LA Spec.
Power Source
USB bus-power (+5V)
Static Power Consumption
0.9W
Max Power Consumption
<6W
Hardware Interface
USB 3.0
Timing Analysis (Asynchronous,Max. Sample Rate)
2 GHz
State Clock Rate (Synchronous,External Clock)
200 MHz
Storage
Conventional Timing, Transitional Timing
Channels
16
Total Memory
4Gb
Timing Analysis
Available Chs (Conventional / Transitional Timing) - Memory per Ch
4GHz Timing [Available Chs] - Memory per Ch
2GHz Timing [Available Chs] - Memory per Ch
[4/3] - 1Gb
1GHz Timing [Available Chs] - Memory per Ch
[8/6] - 512Mb
500MHz Timing [Available Chs] - Memory per Ch
[16/12] - 256Mb
250MHz Timing [Available Chs] - Memory per Ch
[16/16] - 256Mb
Channel to channel skew
< 1ns
Input channels
N/A
Input impedance
1MΩ//2pF
Max. (Non-destructive)
over ±42V DC & AC
Input operation
±20V / ±10V (Standard / High Resolution)
Input sensitivity
200MHz (1Vpp)
Threshold group
2 (CH0~7 & CKI, CH8~15)
Threshold range
±20V
Threshold resolution
50mV
Threshold accuracy
±100mV + 5%*Vth
Trigger resolution
500ps
Trigger types
Channel, Pattern, Single / Multi Level, Width, Time-out, Setup/Hold Timing Violation, External, Manual
Protocol Trigger
BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1.1, SENT, SPI, UART (RS232), USB PD 3
Protocol Analyzer
BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1.1, SPI, UART (RS232), USB PD 3