The LA4000 series offers superior performance in both timing analysis and state analysis compared to the LA3000+. The LA4000 model achieves a frequency of 4 GHz in timing analysis and an impressive 400 MHz in state analysis, making it an ideal choice for logic analysis in high-speed data transmission, communication protocol analysis, and handling complex signal structures.
The LA4068E logic analyzer is a versatile tool, providing comprehensive support with its 68 channels. It addresses various application scenarios, from analyzing signal structures to decoding and debugging communication protocol buses. Commonly used in the development and debugging of ADC and FPGA chips, it provides robust support for signal analysis, communication protocol decoding, and bus analysis.
The LA4000 series also supports stacking measurements with various oscilloscopes through the MCX to BNC cable, facilitating seamless connections with oscilloscopes from other brands such as Keysight, R&S, Tektronix, Acute TravelScope, and more.
Whether in applications requiring high-speed timing analysis or dealing with complex state analysis, the LA4000 series proves to be a reliable partner, offering robust support and versatile applications for your measurement tasks.
Software Window: MIPI I3C (LA Mode) :
MIPI I3C (PA Mode):
Logic Analyzer (LA) Mode
• Capture digital waveforms and support bus decodes. Able to stack with a DSO to form as an MSO.
• Provides multiple storage modes, users could select to have long time recording or precision acquisition.
• Long Time Record: Transitional Storage VS Compressed Storage
For signal capture and analysis, usually require to record the signal for a long time. If the data is stored in a compressed way, it will cause your software to lag or even stop functioning when decompressing the data after it is sent back to the computer. Because PC memory size might insufficient for decompressed data size. To satisfy the requirement of smooth software operation and long-term recording without missing any data, the storage method adopted by the Acute analyzer is transitional storage rather than compression. After returning to the PC software, it doesn"t need to do the decompression. The decoded results can be displayed while the analysis is finished.
Parallel Clause Triggers 16-States parallel IF Clause settings for 128/64 channel value compare combined with AND/OR logic condition and 4 Timer/Counter conditions.
Flow chart bus triggers
Power trigger for serial bus, 8-states flow chart setting with Counter/Timer
Detail parameters for each states
Stack With Other Vendors of Oscilloscope
Add Notes & Pictures in Waveform
Protocol Analyzer (PA) Mode It is hardware decoding, may log protocol data very long time if without waveforms. Application timing: Preliminary protocol debug.
Protocol Analyzer Show real-time protocol data. Application timing: massive protocol data with some idles in between.
Protocol Logger Like data logger, save massive data into SSD hard drive. Application timing: massive protocol data.
Protocol Monitor Like dash cameras, record protocol data by the device’s memory only. Application timing: trigger event only happens in very long time.
LA Spec.
Power Source
12V Power adapter
Static Power Consumption
18W
Max Power Consumption
45W
Hardware Interface
USB 3.0
Timing Analysis (Asynchronous,Max. Sample Rate)
4GHz
State Clock Rate (Synchronous,External Clock)
400MHz
Storage
Conventional Timing, Transitional Timing
Channels
68
Total Memory
32Gb
Timing Analysis
Available Chs (Conventional / Transitional Timing) - Memory per Ch
4GHz Timing [Available Chs] - Memory per Ch
[16 / 16]-2Gb
2GHz Timing [Available Chs] - Memory per Ch
[32 / 32]-1Gb
1GHz Timing [Available Chs] - Memory per Ch
[64/ 56]-500Mb
500MHz Timing [Available Chs] - Memory per Ch
[64 / 64]-500Mb
250MHz Timing [Available Chs] - Memory per Ch
[64 / 64]-500Mb
Channel to channel skew
250 ps
Input channels
N/A
Input impedance
~ 55KΩ || <2pF to 1Vdc
Max. (Non-destructive)
±40V
Input operation
±15V
Input sensitivity
~300mV
Threshold group
N/A
Threshold range
±15V
Threshold resolution
10mV
Threshold accuracy
±100mV + 5%* Vth
Trigger resolution
250 ps
Trigger types
Channel, Pattern, Single / Multi Level, Parallel Clause, Width, Time-out, External
Protocol Trigger
BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SENT, SPI, UART (RS232), USB PD 3
Protocol Analyzer
BiSS-C, CAN2.0B/CAN FD, DP_Aux, HID over I2C, I2C, I2S, LIN2.2, MIPI I3C 1.1, SPI, UART (RS232), USB PD 3